CAE_G-6Ai2Tmp-04

I/O Brick_General-Purpose:
6x Analog-Input, 0/4..20mA, 2/3-wire
2x Temperature, PT1000, 2-wire, 0..50°C

CAE_P-2LfTmp-01

I/O Brick_Process-Control:
2x LF-Input, conductive, 2-wire
1x Temperature, KTY2k

CAE_P-2LfTmp-02

I/O Brick_Process-Control:
2x LF-Input, conductive, 2-wire
1x Temperature, PT1000

CAE_P-IsoTmpAoDAioImp-01

I/O Brick_Process-Control:
1x Current-Input, isol., 3-wire
1x Temperature, KTY2K, -10-50°C, 2-wire
1x Analog Output, 0-20mA, 2/3-wire
1x Analog Input, 20mA, 2/3-wire
1x Pulse-In-/Output, n/p-switch, 2/3-wire
can be used also as a Digital-Input

CAE_P-IsoTmpAoDAioImp-02

I/O Brick_Process-Control:
1x Current-Input, isol., 3-wire
1x Temperature, KTY2K, -10-50°C, 2-wire
1x Analog Output, 0-20mA, 2/3-wire
1x Analog Input, 10V, 2/3-wire
1x Pulse-In-/Output, n/p-switch, 2/3-wire
can be used also as a Digital-Input

CAE_P-LfTmp2Pi2AiAo-01

I/O Brick_Process-Control:
1x LF-Input, conductive
1x Temperature, PT100, -10..50°C
2x Analog Input, 0/4..20mA
2x Pulse-In, npn, can also be used as a Digital-Input
1x Analog Output, 0-20mA

CAE_P-LfTmp2Pi2AiAo-02

I/O Brick_Process-Control:
1x LF-Input, conductive
1x Temperature, PT100, -10..50°C
2x Analog Input, 0..10V
2x Pulse-In, pnp, can also be used as a Digital-Input
1x Analog Output, 0-20mA

CAE_P-LfTmp2Pi2AiAo-03

I/O Brick_Process-Control:
1x LF-Input, conductive
1x Temperature, KTY2k, -10..50°C
2x Analog Input, 0/4..20mA
2x Pulse-In, pnp, can also be used as a Digital-Input
1x Analog Output, 0-20mA

CAE_P-LfTmpAoDAioImp-01

I/O Brick_Process-Control:
1x LF-Input, conductive, 2-wire
1x Temperature, KTY2K, 2-wire
1x Analog Output, 0..20mA
1x Analog Input, 0..20mA, 2/3-wire
1x Pulse-In-/Output, n-switch, 2/3-wire
can also be used as a Digital-Input

CAE_P-LfTmpAoDAioImp-02

I/O Brick_Process-Control:
1x LF-Input, conductive, 2-wire
1x Temperature, KTY2K, 2-wire
1x Analog Output, 0..20mA
1x Analog Input, 0..10V, 2/3-wire
1x Pulse-In-/Output, n-switch, 2/3-wire
can also be used as a Digital-Input

CAE_P-LfTmpAoDAioImp-03

I/O Brick_Process-Control:
1x LF-Input, conductive, 2-wire
1x Temperature, PT100, 2-wire
1x Analog Output, 0..20mA
1x Analog Input, 0..20mA, 2/3-wire
1x Pulse-In-/Output, n-switch, 2/3-wire
can also be used as a Digital-Input

CAE_P-pHTmpAoDAioImp-01

I/O Brick_Process-Control:
1x pH-Input, 2-wire
1x Temperature, KTY2K, -10-50°C, 2-wire
1x Analog Output, 0-20mA, 2/3-wire
1x Analog Input, 20mA, 2/3-wire
1x Pulse-In-/Output, n/p-switch, 2/3-wire
can be used also as a Digital-Input

CAE_P-pHTmpAoDAioImp-02

I/O Brick_Process-Control:
1x pH-Input, 2-wire
1x Temperature, KTY2K, -10-50°C, 2-wire
1x Analog Output, 0-20mA, 2/3-wire
1x Analog Input, 10V, 2/3-wire
1x Pulse-In-/Output, n/p-switch, 2/3-wire
can be used also as a Digital-Input

Go to Top